Item   Detail

Scan type: RFID  

Operating range 12V DC

Control unit encasement: 16 gauge steel   8" x 8" x 5"; lift-off cover
Current consumption: 120V AC   @200ma (typical)

Electrosensors: 5 ship with control unit  

12" x 2" fire-retardant PVC brackets

Response time   .1 to 3 seconds
Operating range   +/- 3"
Angular displacement   6"
Positional mounting tolerance   +/- 1.5"
DoorSaver output contacts   Operation @5A/125V
MagnaLatch housing   4" x 5.5" x 2"; universal mounting flange
Bistable Solenoid   16V DC@1.5A

Solenoid position monitor  

Micro switch; 5A@120V AC

Locking block   5" x 5" x 2"; universal mounting flange
Door position sensors   Magnetic proximity type; neodymium magnet slug
Target alignment indicators   Red LED and 85dB tone generator
Magnalatch housing cable   18 gauge 5 conductor with neoprene jacket
Approval   CSE/UL